Biomechanical design of a composite femoral prosthesis to investigate the effects of stiffness, coating length, and interference press fit
(
Elsevier Ltd
, 2018 , Article)
Traditionally, high stiffness hip prostheses are associated with aseptic loosening. Hence, the effects of stiffness, coating length, and interference press fit on load sharing and micro-movements are investigated for a ...
Finite element modelling and characterization of 3D cellular microstructures for the design of a cementless biomimetic porous hip stem
(
Elsevier Ltd
, 2018 , Article)
Titanium porous cellular microstructures are commonly used in bone mimetic implants. The orientations of the internal strut architectures of these microstructures affect the mechanical performance under various loads; ...
Experimental results and modelling of corrosion-damaged concrete beams strengthened with externally-bonded composites
(
Elsevier Ltd
, 2018 , Article)
This paper presents the results of 3D finite element (FE) modelling of corrosion-damaged reinforced concrete (RC) beams strengthened in flexure with externally-bonded composites. The models were validated against the results ...