Search
Now showing items 1-10 of 10
Analytic comparison between three high-throughput commercial SARS-CoV-2 antibody assays reveals minor discrepancies in a high-incidence population
(
Nature Research
, 2021 , Article)
Performance of three automated commercial serological IgG-based assays was investigated for assessing SARS-CoV-2 "ever" (past or current) infection in a population-based sample in a high exposure setting. PCR and serological ...
Performance evaluation of five ELISA kits for detecting anti-SARS-COV-2 IgG antibodies
(
Elsevier
, 2020 , Article)
ObjectivesTo evaluate and compare the performances of five commercial ELISA assays (EDI, AnshLabs, Dia.Pro, NovaTec, and Lionex) for detecting anti-SARS-CoV-2 IgG. Methods70 negative control samples (collected before the ...
Can commercial automated immunoassays be utilized to predict neutralizing antibodies after SARS-CoV-2 infection? A comparative study between three different assays.
(
IMR
, 2021 , Article)
Background: High-throughput assays that can infer neutralizing activity against SARS-CoV-2 are of great importance for assessing the immunity induced by natural infection and COVID-19 vaccines. We aimed to evaluate the ...
Low risk of serological cross-reactivity between the dengue virus and SARS-CoV-2 IgG antibodies using advanced detection assays.
(
Karger
, 2022 , Report)
Several studies have reported serological cross-reactivity of the immune responses between SARS-CoV-2 and DENV. Most of the available studies are based on the point of care (POC) rapid testing kits. However, some rapid ...
Bacterial indoor air contaminations in hospitals in MENA region: a systematic review
(
Taylor and Francis
, 2022 , Article Review)
Poor indoor air quality in healthcare settings has been tied with the increase in hospital-acquired infections. Thus, this systematic review was conducted to assess the levels and compositions of bacteria in indoor hospital ...
Assessment of Indoor Air Quality of Four Primary Health Care Centers in Qatar.
(
MDPI
, 2022 , Article)
Airborne bacteria pose a potential risk to human health upon inhalation in the indoor environments of health care facilities. Airborne bacteria may originate from various sources, including patients, workers, and daily ...
Neutralizing antibodies against SARS-CoV-2 are higher but decline faster in mRNA vaccinees compared to individuals with natural infection.
(
Oxford University Press
, 2022 , Article)
Waning protection against emerging SARS-CoV-2 variants by pre-existing antibodies elicited due to current vaccination or natural infection is a global concern. Whether this is due to the waning of immunity to SARS-COV-2 ...
Evaluation of commercially available fully automated and ELISA-based assays for detecting anti-SARS-CoV-2 neutralizing antibodies
(
Nature Research
, 2022 , Article)
Rapid and accurate measurement of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV2)-specific neutralizing antibodies (nAbs) is paramount for monitoring immunity in infected and vaccinated subjects. The current ...
Performance evaluation of novel fluorescent-based lateral flow immunoassay (LFIA) for rapid detection and quantification of total anti-SARS-CoV-2 S-RBD binding antibodies in infected individuals
(
Elsevier
, 2022 , Article)
The vast majority of the commercially available LFIA is used to detect SARS-CoV-2 antibodies qualitatively. Recently, a novel fluorescence-based LIFA test was developed for quantitative measurement of the total binding ...
Diagnostic Efficiency of Three Fully Automated Serology Assays and Their Correlation with a Novel Surrogate Virus Neutralization Test in Symptomatic and Asymptomatic SARS-COV-2 Individuals
(
MDPI
, 2020 , Article)
Abstract: To support the deployment of serology assays for population screening during the
COVID-19 pandemic, we compared the performance of three fully automated SARS-CoV-2 IgG assays: Mindray CL-900i® (target: spike [S] ...