بحث بسيط
السجلات المعروضة 21 -- 27 من 27
High-voltage pulse generator based on capacitor-diode voltage multiplier centrally fed from dc-dc boost converter
(
Institution of Engineering and Technology
, 2016 , Conference Paper)
High voltage pulse generators are commonly used in water treatment applications. In this paper, a high voltage pulse generator with closed loop control on its output voltage is presented. The high-voltage pulse generator ...
Multi-module high voltage pulse generator based on DC-DC boost converter and CDVMs for drinking water purification
(
Institute of Electrical and Electronics Engineers Inc.
, 2016 , Conference Paper)
High pulsed electric field (PEF) can be used effectively in drinking water purification, by applying it across the water sample to be treated. Application of sufficient high PEF guarantees killing of harmful germs and ...
GridConnected CapacitorTapped MultiModule Voltage Source Converter
(
Hamad bin Khalifa University Press (HBKU Press)
, 2018 , Conference Paper)
In this work, a new dc-ac converter is proposed for grid integration purposes, namely, capacitor-tapped multi-module dc-ac voltage source converter. The main advantages of the proposed converter when compared with the ...
A five-phase induction machine model using multiple DQ planes considering the effect of magnetic saturation
(
Institute of Electrical and Electronics Engineers Inc.
, 2014 , Conference Paper)
Multiphase phase induction machines are usually modeled using multiple dq planes, where complete decoupling between these sequence planes is usually assumed. This assumption may be accepted if the magnetic circuit is assumed ...
Maximum Power Transfer Of Pv-fed Inverter-based Distributed Generation With Improved Voltage Regulation Using Flywheel Energy Storage Systems
(
Hamad bin Khalifa University Press (HBKU Press)
, 2016 , Conference Paper)
One of the main issues accompanied with the high penetration of PV distributed generation (DG) systems in low voltage (LV) networks is the overvoltage challenge. The amount of injected power to the grid is directly related ...
Transformer-less Grid-Connected High-Voltage Marx Pulse Generator with Unity Power Factor for Domestic Drinking Water Disinfection
(
Hamad bin Khalifa University Press (HBKU Press)
, 2016 , Conference Paper)
Qatar has no rivers, thus the main natural water resource in Qatar is the groundwater table. The average groundwater recharge from rainfall is approximately 55.9 million m3/year, in addition to 2.2 million m3/year inflow ...
Fault-tolerant control of five-phase current source inverter for medium-voltage drives
(
Institution of Engineering and Technology
, 2014 , Conference Paper)
Multiphase Machines offer a promising solution to many practical challenges due to their advantages over the three phase counterparts, as fault-tolerant capability and lower torque ripple magnitude. Among different multiphase ...