Search
Now showing items 1-5 of 5
Sensorless field oriented control of five-phase induction machine under open-circuit phase faults
(
IEEE
, 2013 , Conference Paper)
Recently, multiphase machine is promoted to replace three-phase drives in high power safety-critical applications. Among the numerous advantages of multiphase induction machine drives, operation and self-starting under ...
A voltage-behind-reactance model of five-phase induction machines considering the effect of magnetic saturation
(
IEEE
, 2013 , Article)
Five-phase induction machines are generally modeled using multiple dq planes or using a phase variable model. This paper considers modeling five-phase induction machines using a voltage-behind-reactance (VBR) configuration. ...
Vector control of multiphase induction machine under open-circuit phase faults
(
IEEE Computer SocietyIEEE
, 2013 , Conference Paper)
Multiphase induction machine is normally controlled using rotor field oriented vector control. Under phase(s) loss, the machine currents can be optimally controlled to satisfy certain optimization criteria. In this paper, ...
Open loop V/f control of multiphase induction machine under open-circuit phase faults
(
IEEE
, 2013 , Conference Paper)
One of the main advantages of multiphase induction machines is their higher fault-tolerant capability. Under phase(s) loss, the machine currents can be optimally controlled to satisfy certain optimization criteria. In this ...
A power control strategy for flywheel doubly-fed induction machine storage system using artificial neural network
(
Elsevier Ltd
, 2013 , Article)
A large-capacity low-speed flywheel energy storage system (FESS) based on a doubly-fed induction machine (DFIM) consists of a wound-rotor induction machine and a back-to-back converter rated at 30-35% of the machine power ...